Sync methods – which one to choose
IT Glue supports integrating between multiple data sources. This article will help you understand the 4 different methods of integrating RMM and PSA tools.
Choosing a sync method
Make sure that you read through each of the steps below that apply to the method you've decided on before importing and syncing data from external sources.
If you're using a supported PSA tool, we recommend that you connect your PSA to IT Glue first. With PSA syncing set up, your organizations, locations, and contacts will appear without any extra effort on your part. You can also sync configurations from your PSA with minimal effort.
If you choose to add an RMM, IT Glue will try to discover data in your RMM and match it to any existing IT Glue data, which includes PSA data. For RMM organizations and configurations to be automatically matched, the organization names and the device serial numbers or MAC addresses must match. For more on RMM integrations and the caveats with respect to RMM imported data, take a look at our About RMM configuration integrations article. For the detailed matching logic, see the integration articles that we created for each RMM.
There are 4 sync methods available to choose from:
Method | Description |
PSA only, no RMM (option A) |
|
PSA and RMM for a combined view of configuration data (option B) |
|
PSA, syncing only organizations, contacts, locations |
|
RMM only, no PSA (option D) |
|
NOTE Two-way PSA syncing is currently only available for ConnectWise, Autotask, Kaseya BMS, and Pulseway PSA. Also note that configuration sync is not available for Tigerpaw integrations.
Process for integrating
A. PSA only
- Integrate your RMM with your PSA tool.
- Push all RMM data to your PSA.
- Add your PSA integration to IT Glue.
- Make sure that you enable the relevant options on the sync settings screen (e.g. Managed Servers, Managed Workstations).
- Wait for the full PSA sync to complete. Data will be written to your account according to the enabled options in your sync settings.
NOTE For the field mapping and other details, see the integration articles that we created for each PSA.
Diagram: Data from PSA is synced with IT Glue (option A)
If a one-way PSA sync is chosen, IT Glue will not update your PSA.
B. PSA and RMM (recommended)
- Integrate your RMM with your PSA tool.
- Push all RMM data to your PSA.
- Add your PSA integration to IT Glue.
- Select the configuration types you'd like to sync with IT Glue.
- Wait for the full PSA sync to complete. Data will be written to your account according to the enabled options in your sync settings.
- Add your RMM integration to IT Glue.
- Wait for the full RMM sync to complete.
- From the matching screens, manually action unmatched organizations and configurations. Most of this information should be matched automatically.
NOTE For the matching logic and other details, see the integration articles that we created for each RMM.
IMPORTANT Warning. With this sync method, don't use the RMM matching screens to create new organizations or configurations in IT Glue because you'll automatically get the same RMM data from a PSA sync. This should allow everything to match automatically and it avoids duplicates.
Diagram: Data from RMM is synced with PSA and IT Glue; PSA and IT Glue continue to sync (option B)
If a one-way PSA sync is chosen, IT Glue will not update your PSA.
C. PSA and RMM - without PSA configurations
This process is similar to the RMM only method because you're relying on the RMM to provide configuration data, but with the benefit of having your PSA synced organizations, locations, and contacts appear without any extra effort on your part.
- Add your PSA integration to IT Glue but do not enable any Configuration Types in the sync settings.
NOTE If you have configurations in IT Glue syncing from your PSA, now is a good time to disconnect them and disable the PSA configuration sync for Managed Servers, Managed Workstations, etc. If you're at all unsure, speak with us before completing this process.
- Wait for the full PSA sync to complete. Data will be written to your account according to the enabled options in your sync settings.
- Add your RMM integration to IT Glue.
- Wait for the full RMM sync to complete.
- From the matching screens, manually action (match, ignore, create) unmatched organizations and configurations.
NOTE For the matching logic and other details, see the integration articles that we created for each RMM.
IMPORTANT Warning. With this sync method, you shouldn't use the RMM matching screens to create new organizations in IT Glue because you'll automatically get this information from a PSA sync. Otherwise, it could create a duplicate.
Diagram: Data from RMM is synced with IT Glue; PSA and IT Glue continue to sync but without configurations data (option C)
If a one-way PSA sync is chosen, IT Glue will not update your PSA.
D. RMM only
- (Optional) Import any relevant data from Network Detective or spreadsheets (.csv files containing organizations, locations, contacts, and configurations).
- Select your RMM to integrate it with IT Glue.
- If you're currently integrated with a PSA, disconnect your PSA before connecting your RMM. You'll usually want to keep all of the data imported from your PSA, but if you're at all unsure, speak with us before completing this process.
- Wait for the full RMM sync to complete.
- From the matching screens, manually action (match, ignore, create) unmatched organizations and configurations.
NOTE For the matching logic and other details, see the integration articles that we created for each RMM.
Diagram: Data from RMM is synced with IT Glue (option D)